PHARMACEUTICAL APPLICATION STUDIES
The reports listed below are written by the food scientist at Stable Micro Systems. All the reports are available as part of the Texture Expert software packages Help system. If you would like to see any of these application studies and you do not have the Texture Expert software or your version does not have the required study then e-mail app.support@stablemicrosystems.com and quote the Reference number. Remember to provide your company name and return address or fax details.
|
Compressed Face Powders |
|
|
SHAD1/P2 |
Comparison of hardness or 'cake strength' of two eyeshadows |
|
Deodorant |
|
|
DEO1/P2 |
Comparison of hardness of two different formulations of deodorants by penetration with a 2mm cylinder probe |
|
Gel Capsules |
|
|
GCP1/P2 |
Comparison of rupture force and elasticity of four gel capsule types by penetration with a 2mm cylinder probe |
|
Hair Gel |
|
|
GEL5/BEC |
Comparison of consistencies of two types of hair gel by back extrusion |
|
Hypodermic Needles |
|
|
NEED1/TG |
Comparison of sharpness of hypodermic needles by penetration through a rubber stopper |
|
Lipstick |
|
|
LIP1/P2N |
Comparison of hardness of two different lipstick batches by penetration with a 2mm needle probe - according to ASTM Standard method D 1321-95 |
|
LIP2/LC |
Comparison of bending force of lipsticks at 2 storage temperatures using a Cantilever Test |
|
LIP3/P2N |
Comparison of hardness of two different lipstick batches by penetration with a 2mm needle probe- an adaptation of ASTM Standard method D 1321-95 |
|
Medical Adhesive Tape |
|
|
MAT1/P025 |
Comparison of adhesiveness of medical adhesive tapes by testing with a ball probe through a multi-hole indexing system |
|
Moisturising Cream |
|
|
CRM1/BEC |
Comparison of consistencies of three moisturising creams by back extrusion |
|
Petroleum Jelly |
|
|
PET1/SR |
Spreadability/Softness of petroleum jelly stored at 5°C and 25°C |
|
Shampoo |
|
|
SHA1/BEC |
Comparison of consistencies of two shampoos by back extrusion |
|
Soap |
|
|
SOA1/P2 |
Comparison of hardness of two different types of soap bars by penetration with a 2mm probe |
|
Tablets |
|
|
TAB1/P25 |
Failure behaviour of tablets due to diametral compression using a cylinder probe |
|
TAB2/TCA |
Measurement of tablet coating adhesion force |
|
Tablet Granules |
|
|
GRN1/P25 |
Compressibility of tablet granules using a cylinder probe |
|
Toothpaste |
|
|
TPT1/TER |
Comparison of toothpaste firmness / 'force to extrude' of two toothpaste formulations |
|
Transdermal Delivery Systems |
|
|
PCH/P025 |
An investigation into the adhesiveness of transdermal delivery patches by probing with a ball probe through a holed plate |
|
Wax |
|
|
WAX1/45C |
Comparison of hardness of two wax types by penetration with a cone probe - according to ASTM Standard method D937-92 |
|
WAX2/P1S |
Comparison of stickiness properties of two types of soft moulding hair wax using a 1" ball probe |
|
WAX3/P1S |
Measurement of the stickiness properties of hair removal wax with a spherical probe |